Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)
  • Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)
  • Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)
  • Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)
  • Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)
  • Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)
Find Similar Products

Basic Info.

Model NO.
RLS
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Gas
Installation
Fixed
Structure
Conventional Circuit Breaker
Poles Number
3
Type
Circuit Breaker
Function
Overcurrent Protection, Circuit-Breaker Failure P
Certification
ISO9001-2000, CE
Transport Package
Wooden Packing
Specification
IEC, GB
Trademark
Rockwill
Origin
China
HS Code
8535210000
Production Capacity
1000 PCS/Year

Product Description

++++General:

     RLS-36 an indoor high-voltage SF6 load switch, an swi tchgear wi ththe rated voltage of 36kV/40.5kV, adopted wi th SF6 gas as an arc-extinguishing and insulation medium, including the three contactors for switching-on and switching-off andto-ground, and is characteristic in its small volume, its convenient installation and operation and itsthe great adaptability with surroundings. RLS-36 of an indoor high-voltage SF6 load switch and RLS-36 of SF6 load switch plus fuse combination canfunctionto protect and controlthe electric equipmentsfor power supply andtransformer substations especially being suitable for ring net cabinet, cable branch cabinet and distribution switching substation. 

     RLS-36 of an indoor high-voltage SF6 load switch and RLS-36 load switch plusfuse combination are complied withthe standards of GB3804-1990, IEC60256-1,1997, GB16926, IEC60420 etc.. 


++++Service environment:

     a) Airtemperature Maximumtemperature: +40ºC; Minimumtemperature:-5ºC
     b) Humidity Monthly average humidity 95%; Daily average humidity 90%. 
     c) Altitude above sea level Maximum installation altitude: 2500m 
     d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. 
     e) Nofrequent violent shake

++++ Main technical specifications:
 

 No

   Item

  Unit 

 Parameter

  1 

   Rated voltage 

  kV

   36

 2 

  Rated frequency

 Hz 

    50/60

 3 

  Rated current

  A

   630

 4

                                                  wet

 1min Power frequency withstand voltage 

                                                  dry

   kV 

 

 kV

  95  

 

 110   

 5

  Lightning impulse withstand voltage 

   kV 

  185/215

 6

  Rated short circuit breaking current (peak)

   kA

 50

  7 

         Rated activeload and close circuit breaking current

   A 

  50

 8

 Rated transferring current 

  A 

   1000

 9 

  Rated short circuit making current (peak) 

  kA 

  50

 10

   Rated cable(line) charging breaking current

  A 

  50 and 10

  11 

  Cable charge breaking current in earthing fault 

 A

   20

 12

 Rated withstand current (peak)

 kA

   50

 13

 Short time withstand current (2s)

     kA

   20

 14

  Mechanism life

 times

 2000

Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)Rls 36kv 1250A-16ka Indoor Manully Operation Indoor Rmu Use Sf6 Switch Disconnector Load Break Switch (LBS)