• Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
  • Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
  • Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
  • Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
  • Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
  • Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear

Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear

Certification: ISO9001
Shell Material: Aluminum Alloy
Voltage Level: High Voltage
Installation: Fixed
Structure: Floorstanding
Current: AC
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RMR
Transport Package
Wooden Packing
Specification
IEC, GB
Trademark
Rockwill
Origin
China
HS Code
8535210000
Production Capacity
10000

Product Description

General

RMR-36/40.5kV is completely insulated SF6 Gas insulated Switchgear.
This product is in conformity with the standards the GB/IEC standard and the design of a high safety combined switch cabinets.

The system of RMR-36/40.5kV of combined switch cabinets can be divided into three kinds of unit cabinet:

++++ 3 position cable connection unit (Cable switch unit), additional live shows and configuration of surge arresters and grounding fault component. Code C

++++3 position switch and fuse tripping system and earthing switch interlock system fuse combined electrical unit (Fuse combination unit), additional live shows and configuration of surge arresters and grounding fault component. Code F

++++3 position switch and vacuum circuit breaker combined appliances unit (Vacuum circuit breaker unit), additional current transformer, live shows and configuration of surge arresters and grounding fault component. Code V

The combination of the current transformer and the microcomputer protection to constitute the basic circuit protection function.

Microcomputer protection using passive protection and CT electric no need of additional PT

Main technical specifications

 
No Item Unit Data
1 Rated voltage kV 24/36
2 Power Frequency withstand voltage Dry 60/70/80/95
Wet
Lightning Impulse withstand Voltage
(peak value)
125/150/170/185/200
3 Rated Current A 630/1250/2500
4 Rated short circuit breaking current (peak) kA 20/25(V) 31.5(F)
5 Rated closed-loop breaking current A 630/1250(C)
6 Rated cable charging interrupting current A 50(C)
7 Rated line cable charging interrupting current A 10(C)
  Rated off circuit transformer breaking current A 16
8 Rated making current (peak) kA 50(63/80)/2.5(main switch/grounding)
9 Rated  withstand current (peak)
10 Rated short time withstand current 16/20/25/31.5
11 Rated short time withstand time S 3/4
12 Mechanical life times C/F(2000)V(10,000)
13 Main busbar A 630/1250/2000/2500
More details pls consult with us!Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear
Indoor /Outdoor Type 12kv Metal-Enclosed Sf6 Gas Insulated Ringmain Unit Switchgear

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate