24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)

Product Details
Customization: Available
Transport Package: Wooden
Trademark: Rockwill
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • 24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
  • 24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
  • 24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
  • 24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
  • 24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
  • 24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
Find Similar Products

Basic Info.

Model NO.
RPS
Origin
China
HS Code
8535210000
Production Capacity
1000PCS

Product Description

SF6 Gas Insulated  pole mounted Load Break Switch with KEMA test report (LBS)

Polemount LBS with Manual operation mechanism

- Pole mounted SF6 Gas insulated load break switch (Pole mounted switch disconnector) type RPS-12/27/38-20 is suitable for the rated voltage up to 40.5kV,rated current 400A-630A, 50/60Hz power system.

-RPS type polemount LBS is SF6 breaking on load break switch, ie. on load switch disconnector.
Rated voltage: up to 40.5 kV
Rated current: 400 to 630 A
Insensitive to the environment.

Options:

E2/E3

Manual or remote control

CT/PT/VS 
Gas pressure guage

Low pressure lockout

SCADA capabilities
etc...


· Summary

ROCKWILL® Electric strives to bring our customers the latest technology and competitive pricing and best service for distribution automatic.
RPS is an SF6-insulated, outdoor pole mounted load break switch family for overhead lines and specifically designed for use in modern remote controlled distribution automation systems. The RPS offers reliable maintenance free operation even in the most demanding climatic conditions including salt laden atmospheres, corrosive industrial pollution, snow and ice. It has excellent load breaking and fault making capacity and satisfies the isolation requirements specified for load break switch. The earthed metal tank prevents all possible leakage currents across an open switch. RPS can be manually operated or motor operated for local and remote electric control, upgraded.

·Service environment

1.Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
Humidity: Monthly average humidity 95%; Daily average humidity 90% .
Altitude above sea level: Maximum installation altitude: 2500m or more higher.
Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. No frequent violent shake

·Offering

With optional classes for rated current range:
--Type RPS 15, Rating6-20 kV with 400A, 16 kA up to 1250A, 20kA;
--Type RPS 27, Rating22-27 kV with 400A, 16 kA up to 1250A, 20kA;
--Type RPS 38, Rating30-40.5 kV with 400A, 16 kA up to 1250A, 20kA;
With optional classes for different grid application installation:
Section function (Section)
50 Instantaneous/Definite-Time Overcurrent(P.OC)
51 Phase Time-Overcurrent(P.Fast curve/P.Delay curve)
Overload (N.Fast curve/N.Delay curve)
50N Residual Ground Instantaneous/Definite-Time Overcurrent(G.OC)
51N Residual Ground Time-Overcurrent (G.Fast curve/G.Delay curve)
50SEF Sensitive Earth Fault (SEF)
51c Cold Load(Cold load)
TRSOTF Switch-Onto-Fault(SOTF)
59 Over Voltage(L.Over volt)
27 Under Voltage (L.Under volt)
Monitoring Functions: 
Primary/Secondary Phases and Earth Currents 
Direction 
Primary/Secondary Line and Phase Voltages 
Apparent Power and Power Factor 
Real and Reactive Power 
Historical Demand Record 
Positive Phase Sequence Voltage & Current 
Negative Phase Sequence Voltage & Current 
Zero Phase Sequence Voltage 
Frequency 
Binary Input/Output status 
Trip circuit healthy/failure 
Time and date 
Fault records 
Event records

 

·Time-Overcurrent Curves

The following information describes the curve timing for the curve and time dial settings made for the time-overcurrent elements The time-overcurrent relay curves in conform to IEEE C37.112-1996 IEEE Standard Inverse-Time Characteristic Equations for Overcurrent Relays.
 

24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)

 Creepage Distances of RPS

Terminal to ground creepage 15kV BIL 95/110kV 27kV BIL125/150kV 38kV BIL 170/200kV
Composite bushing 564mm 840mm 1400mm
Porcelain bushing 556mm 708mm 1250mm


·Current transformer and Voltage sensor

Part Number RPS-15 RPS-27 RPS-38
Manual Motorize Manual Motorize Manual Motorize
Current transformer / 3 / 3 / 3
Voltage sensor / 3/6 / 3/6 / 3/6

Note: Current transformers and voltage sensors can be customized according to requirements.

·Standards for reference

IEC 62271-1 IEC 62271-102 IEC 62271-103 
High-voltage switchgear and controlgear. Part 103: switches for rated voltage above 1 kV up to and including 52 kV




24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
Front: Color clear O/C indicator                     Rear:Highly reliable explosion-proof                                                                                                                         valve,Inflatable/deflation integrated device.
 
Insulation level
Rated voltage kV 15 27 38
Power frequency withstand voltage, 50 Hz
- to earth and between phases kV 28 50 70
- across the isolating distance kV 32 60 80
Lightning impulse withstand voltage
- to earth and between phases kV 75 125 170
- across the isolating distance kV 85 145 195
Current ratings
Rated normal current A 400/630/800/1250
Mainly active load breaking current A 400/630/800/1250
Number of breaking operations CO times 400
Line-charging breaking current A 1 1.5 2
Cable-charging breaking current A 10 16 20
Earth fault breaking current A 50 50 130
Cable charging breaking current        
under earth fault conditions A 28 28 80
No-load transformer breaking current A     20
Short-circuit ratings
Short-time withstand current, Ik kA/s 20 kA/4 s 20 kA/4 s 20 kA/4 s
Peak withstand current kA 50 50 50
Short-circuit making current kA 50 50 50
Number of making operations
- main switch 50 kA (CL E3) times 5 5 5
- main switch 31.5 kA (CL E3) times 10 10 10
- earthing switch 50 kA (CL E2) times 3 3 3
- earthing switch 31.5 kA (CL E3) times 5 5 5
Ambient air temperature limits   -40°C...+60°C
Mechanical endurance (number of CO operations)
- main switch times 5000 5000 5000
- earthing switch times 2000 2000 2000
Filling pressure (+20°C) bar (abs) 1.4-1.5 1.4-1.5 1.8-1.9
Alarm pressure (+20°C)
- density switch bar (abs) 1.2 1.2 1.65
- density gauge bar (abs) 1.2 1.2 1.6
- low gas lock-out mechanism bar (abs) 1.1 1.1 1.6
Weight
Composite bushing kg 115 125 135
Porcelain bushing kg 125 135 155
Motorize   Add 20kg
Degree of protection of the mechanism box   IP67
24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)
24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)24kv Sf6 Gas Insulated Pole Mounted Load Break Switch with Kema Test Report (LBS)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier