15kv Autoreclosers Including Vt/CT and Mounting Accessories

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • 15kv Autoreclosers Including Vt/CT and Mounting Accessories
  • 15kv Autoreclosers Including Vt/CT and Mounting Accessories
  • 15kv Autoreclosers Including Vt/CT and Mounting Accessories
  • 15kv Autoreclosers Including Vt/CT and Mounting Accessories
  • 15kv Autoreclosers Including Vt/CT and Mounting Accessories
  • 15kv Autoreclosers Including Vt/CT and Mounting Accessories
Find Similar Products

Basic Info.

Model NO.
RCW
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Conventional Circuit Breaker
Poles Number
3
Type
Circuit Breaker
Function
Overcurrent Protection, Circuit-Breaker Failure P
Certification
ISO9001-2000, Kema
Transport Package
Wooden
Specification
iec
Trademark
Rockwill
Origin
China
HS Code
85352100
Production Capacity
5000

Product Description

33kv High Voltage Outdoor Auto Circuit Recloser with Intelligent Controller


General

Rockwill Electric strives to bring our customers the latest technology and competitive pricing and best service for distribution automatic.

The RCW series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. and its rated current can reach 1250A.

The RCW series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.


Service environment

  a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
  b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
  c) Altitude above sea level: Maximum installation altitude:2500mor more higher.
  d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  e) No frequent violent shake


Main technical data
 
No. item unit data
1 Rated voltage kV 15 27 38
2 Rated current A 630 1250 800
3 Rated frequency Hz 50/60
4 Power frequency 1 min Dry kV 50 65 85
Wet kV 45 55 75
5 Lightning impulse withstand voltage(peak value) alternate, opposite/fracture kV 100 125/150 170
6 Rated short circuit breaking current kA 20 16/25 12.5
7 Rated short current switching current(peak value) kA 50 40/63 31.5
8 Rated peak value withstand current kA 50 40/63 31.5
9 4S short time withstand current kA 20 16/25 12.5
10 Rated operating circulate   O-T1-CO-12s-CO-12s-CO-12s-CO
11 Breaking current frequency under rated short circuit times 30
12 Mechanism life times 10000
13 Secondary loop 1 min power frequency withstand voltage   2
 
15kv Autoreclosers Including Vt/CT and Mounting Accessories



 
15kv Autoreclosers Including Vt/CT and Mounting Accessories
15kv Autoreclosers Including Vt/CT and Mounting Accessories


15kv Autoreclosers Including Vt/CT and Mounting Accessories
15kv Autoreclosers Including Vt/CT and Mounting Accessories
15kv Autoreclosers Including Vt/CT and Mounting Accessories



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier