Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant

Product Details
Customization: Available
Type: Power
Structure: Protection
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
  • Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
  • Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
  • Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
  • Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
  • Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
Find Similar Products

Basic Info.

Model NO.
RMR
Certification
ISO9001:2000, VDE, CCC
Form
All- packaged Type
Operation Voltage
High Voltage
Size
3 Uint
Application Range
Power Plants
Shell Material
Stainless Steel
Shell Protection Grade
IP56
Brand
Rockwill
Transport Package
Wooden Packing
Specification
IEC, GB
Trademark
ROCKWILL
Origin
Zhejiang, China
HS Code
8537209000
Production Capacity
100

Product Description

1.SM66-40.5 unit type
 
SF6 RMU with SF6 load switch as main switch, for whole cabinet is suitable for electric distribution automation and compact also expandable metal close switchgear. It characters in its simple structure, flexible operation, reliable interlocking and convenient installation etc., which can provide the satisfactory technical projects both for different application occasions and users. With the adoption of sensor technology and the protection relay up to date, plus the advanced technology and flexible assembly project, SM66-40.5 unit type SF6 RMU can completely meet the requirement of continuously variable market. It can take self-produced RLS-40.5 load break switch; also according to the demand of users can be assembled with the internationally top-ranking RCB series vacuum circuit breaker with permanent magnetic mechanism made by AREVA or HD4 type SF6 circuit breaker made by AREVA or HD4 type SF6 circuit breaker made by ABB or with our VSC-40.5 type vacuum circuit breaker with permanent magnetic mechanism. Operational methods for the main switch inside ring main unit can be either manual or electric power driven. And It can meet the requirement of "Four Controls" when matched with FTU and RTU.

No. Item Unit Parameter
1 Rated voltage kV 36
2 Rated frequency Hz 50/60
3 Rated current A 1630
4 1min Power frequency withstand voltage kV 80
5 Lightning impulse withstand voltage kV 195
6 Rated short circuit breaking current (peak) kA 50/40
7 Rated active load/close circuit breaking current A 50/40
8 Rated transferring current A 800
9 Rated short circuit making current (peak) kA 50/40
10 Rated cable(line) charging breaking current A 50 and 10
11 Cable charge breaking current in earthing fault A 50
12 Rated withstand current (peak) kA 50/40
13 Short time withstand current (2s) kA 16
14 Mechanism life times 2000



2.OMR unit 

The OMR is with option for different application. as a extensible or non extensible RMU.

The OMR comprising of a Tee off vacuum circuit breaker and two fault-make load break ring switches contained within a common SF6 gas insulated stainless steel enclosure.

The OMR unit is suitable for both indoor and outdoor applications and can be used either as a freestanding unit or for mounting to a transformer, complying with iec62271-200

Service environment:

     a) Air temperature:Maximum temperature: +40ºC; Minimum temperature:-20ºC
     b) Humidity:Monthly average humidity 95%; Daily average humidity 90% .
     c) Altitude above sea level:Maximum installation altitude: 2500m
     d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

Standard instruction:

     D unit configuration
     See standard configuration and features of "Cable connecting module without earth switch module"

     C unit configuration
     See standard configuration and features of "Load break switch module"
     F unit configuration
     See standard configuration and features of "Load break switch and fuse combination module"
     V unit configuration
     See standard configuration and features of " Vaccum switch module"

Standard combinations also includes belowing configurations:

 

    Voltage indicator of incoming bushing capacitive character SF6 density/pressure monitor( gas meter) with each gas cell Ring for lifting Operating handle.


3.SF6 Gas Insulated Ring Main Unit Switchgear

SHXGN(RMR) type SF6 gas insulated ring main unit is integrating with SF6 infill cabinet which gather with LBS, Fuse, ES, DS, etc.

This product is in conformity with the standards of IEC60420, GB/T11022, GB3804, GB3906
Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant

Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant

 Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
 Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant         





Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant
Sf6 Gas Insulated Switchgear for Medium Voltage for Midget Plant

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier