• 3 Pole Withdrawable Type Vacuum Interrupter
  • 3 Pole Withdrawable Type Vacuum Interrupter
  • 3 Pole Withdrawable Type Vacuum Interrupter
  • 3 Pole Withdrawable Type Vacuum Interrupter
  • 3 Pole Withdrawable Type Vacuum Interrupter
  • 3 Pole Withdrawable Type Vacuum Interrupter

3 Pole Withdrawable Type Vacuum Interrupter

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed/Drawable
Structure: Vcb
Customization:

Contact Supplier

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
VD4
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000
Transport Package
Carton
Specification
IEC, GB
Trademark
Rockwill
Origin
China
HS Code
8535210000
Production Capacity
1000PCS

Product Description


Withdrawable circuit-breakers

Description

VD4 series medium voltage vacuum circuit-breakers with lateral operating mechanism feature the separate pole construction technique.

The operating mechanism is the EL trip-free stored energy type with independent opening and closing regardless of the operator's action. The EL operating mechanism is widely used in all VD4 series circuit-breakers with frontal control.

The circuit-breaker can be remote controlled when fitted with dedicated electrical accessories (gearmotor, opening and closing release).

The operating mechanism, the three poles and the current sensors (if installed) are assembled on a metal frame without wheels. The construction is extremely compact, strongly built and low in weight. 

VD4 series circuit-breakers with lateral operating mechanisms are life-long sealed pressure devices (Standards IEC 62271-100 and CEI EN 62271-100). 

Additionally, VD4 series circuit-breakers have been type tested for low temperature and marine applications (Germanischer Lloyd).

VD4 vacuum circuit breakers have been designed for indoor use and air insulated switchboards.
 

Advantages

Vacuum circuit-breakers have particular advantages for use in networks where there is a high switching frequency in the working current range and/ or where a certain number of short- circuit breaking operations are expected. VD4 vacuum circuit- breakers are suitable for auto reclosing and have exceptionally high operating reliability and long life. The circuit- breakers are notable for their compact design, small dimensions together with high capacity. The operating mechanisms have a low maintenance requirement and the interrupters are maintenance- free throughout their service lives. They are well suited to all load breaking operations which occur in practice, and in particular:
  • Short-circuit currents;
  • Overhead lines under load and, no-load conditions;
  • Cables under load and no-load conditions;
  • Transformers under load and no-load conditions;
  • Generators under load and no-load conditions;
  • Ripple control system;
  • Capacitor banks(also parallel switching) and Motors with starting currents above 600A;
 
Fields of application

Below is the list of SM6 range units used in MV/LV transformer substations and industrial distribution substations:
  • Cable control and protection
  • Overhead control and protection
  • Transformers and distribution substations
  • Motor and transformer control and protection
  • Generator control and protection
  • Capacitor bank control and protection
 
Diagrammatic sketch

3 Pole Withdrawable Type Vacuum Interrupter

Circuit-breaker operating mechanism
A Open/closed auxiliary contacts
B Geared motor for closing spring charging
C Built-in closing spring charging lever
D Mechanical signalling device for circuit-breaker open/closed
E Mechanical operation counter
F Plug-socket connectors of electrical accessories in the truck
G Signalling device for closing springs charged/discharged
H Service releases
I Closing pushbutton
L Opening pushbutton
M Operating mechanism locking electromagnet
N Additional shunt opening release
O Transient contact
P Contacts for signalling spring charged/discharged

Main characteristics
 
Circuit-breaker   VD4/W 36
Standards   IEC 62271-100
Rated voltage Ur [kV] 36
Rated insulation voltage Us [kV] 36
Withstand voltage at 50 Hz Ud (1 min) [kV] 70
Impulse withstand voltage Up [kV] 170
Rated frequency fr [Hz] 50
Rated normal current Ir [A] 630 / 1250 / 1600 / 2000 / 2500 / 3150
Rated breaking capacity (rated short-circuit breaking current symmetrical) Isc [kA] 20 / 25 / 31.5 / 40
Rated short-time withstand current (3s) Ik [kA] 20 / 25 / 31.5
Making capacity Ip [kA] 50 / 63 / 80 / 100 / 125
Operation sequence   [O - 0.3 s - CO - 15 s - CO]
Opening time [ms] 33 ~ 60
Arcing time [ms] 10 ~ 15
Total breaking time [ms] 43 ~ 75
Closing time [ms] 30 ~ 60
Operating  temperature [ºC] -5 ~ +  40
 

3 Pole Withdrawable Type Vacuum Interrupter
3 Pole Withdrawable Type Vacuum Interrupter
3 Pole Withdrawable Type Vacuum Interrupter
3 Pole Withdrawable Type Vacuum Interrupter
3 Pole Withdrawable Type Vacuum Interrupter
3 Pole Withdrawable Type Vacuum Interrupter
 

Send your message to this supplier

*From:
*To:
avatar Mr. Chen Chengming
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate