1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards

Product Details
Customization: Available
Application: Power
Phase: Three
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • 1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
  • 1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
  • 1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
  • 1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
  • 1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
  • 1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
Find Similar Products

Basic Info.

Model NO.
zgs
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000
Usage
Combined Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Transport Package
Wooden
Specification
IEC/ANSI/IEEE/BS/GB/DIN
Trademark
Rockwell
Origin
China
HS Code
8504231100
Production Capacity
10000

Product Description


ZGS combined transformer- US style prefabricated substation

Product description


The combination transformer is characterized by reliable power supply, reasonable structure, quick installation, flexible and easy operation, small volume, low construction cost, etc. it is suitable for outdoor and indoor use, and is widely used in industrial parks, residential quarters, business center and high risers.

Feature

Small volume, compact structure, reliable power supply and easy for installation; it can realize single power supply, double power supply, or ring net supply, with double-fuse protection, low running cost.
The casing surface is treated by electrostatic painting and has good wearing resistance. It is applicable to both ring network and single/double power supply, is convenient for shifting, and can enhance the reliability of power supply. The transformers adopts environment-friendly S11 series spiral core, non-excited voltage regulation, full-enclosed type, featuring energy saving and low noise. The amorphous alloy transformer is also available if required by clients. HV load switches and protective fuse are placed in oil filled iron tank, and the tank is of full-enclosed structure. The LV room is provided with watt-hour meters, voltmeter, and breakers of four outgoing lines, reactive power compensation can also be provided if necessary.

It uses S11 series spiral core transformer amplifier, its idle loss is 30%-40% lower than S9, and noise 7-10Db lower than S9.
Model and Meaning

Features
    The oil tank is equipped with 35kV 11type oil-immersed step-up transformer, and the oil tank is fully sealed structure, the radiator is rationally laid, and the high-performance seals, pressure relieve valve, gas relay, oil level gauge, temperature controller are equipped. The advantages are low loss, low noise, low temperature rise, high resistance to short circuit, high overload, no leakage and so on. In addition, the high-voltage load switch and high-voltage fuses are also placed in the oil, the use of transformer oil as an insulating medium, which has a strong electrical performance.
    In addition, high-voltage load switch and high-voltage fuses are also placed in the oil tank, the transformer oil is used as the insulating medium, which makes it has a strong electrical feature.
    The high-voltage room is equipped with enhanced anti-contamination outlet bushing, at the end there set the fully insulated cable contacts, and the arrester is also equipped to reduce the over-voltage risk. The high-voltage room is also equipped with a sensor. Electromagnetic group and live display are employed to prevent misuse.
    Low-voltage room is generally employed the dual-line as the incoming line, and equipped with circuit breaker, disconnector, current transformer, surge arrester and other components, another substation is used in it as a transformer for the entire substation power supply.
    The three compartments are structurally independent and electrically interconnected. This not only ensures the safety and convenience of operations, but also ensures the safety and reliability of operations. The transformer box is designed to employ a unique labyrinth sealing type, coupled with high-performance long-life seals, all the incoming and outcoming line and the vents are equipped with anti-dust chamber, which can effectively prevent dust, rain and snow. This product truly achieves full condition, full insulation, fully sealed, maintenance-free, which ensures that it can be used in the harsh environment for 20 years.

Parameters

Rated Capacity(kVA) Voltage (kV) Vector Group
  
Impedance Voltage (%) No-load Loss     (W) Load Loss
(W)
Total Weight(t) Reference Dimensions(mm)L*W*H
630 High Voltage H.V.
36.75,38.5±2×2.5%
Low Voltage L.V.
0.69-0.69
Dyn11 6.5 810 7820 4 2450*2260*2150
800 980 9350 4.5 2450*2280*2150
900 1070 10450 4.8 2450*2300*2150
1000 1150 11500 5 2520*2340*2150
1250 1370 13850 5.1 2520*2380*2150
1600 1650 16600 6.5 2520*2380*2150

Product Photo
1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards

1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards
1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards


 
1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards1000kVA 13.2kv Three-Phase Pad-Mounted Transformers Comply with IEEE and ANSI Standards

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier