Customization: | Available |
---|---|
Transport Package: | Carton |
Specification: | IEC, GB |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Rated voltage | Un | kV | 12 | 17.5 | 24 | 36 | ||||||||
Rated current | In | A | 400 | 630 | 1250 | 400 | 630 | 1250 | 400 | 630 | 1250 | 630 | 800 | 800 |
I | A | 400 | 630 | 1150 | 400 | 630 | 1150 | 400 | 630 | 1150 | 630 | 800 | 1000 | |
Peak withstand current | Ima | kA peak. | 67 | 67 | 67 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Peak withstand current | Idyn | kA peak. | 82 | 82 | 82 | 82 | 82 | 82 | 82 | 82 | 82 | 66 | 66 | 66 |
Short time current 1 sec. | Ith | kA eff. | 31.5 | 31.5 | 31.5 | 31.5 | 31.5 | 31.5 | 31.5 | 31.5 | 31.5 | |||
2 sec. | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | ||
3 sec. | 20 | 20 | 20 | 16 | 16 | 16 | ||||||||
Mainly active load breaking capacity1)(test duty 1 and 2, IIEC 60265-1 (IEC 265)) | I | A | 400 | 630 | 1250 | 400 | 630 | 1250 | 400 | 630 | 1250 | 630 | 800 | 800 |
Rated cable/line charging breaking capacity IEC 60265-1(IEC 265)) | I | A | 150 | 150 | 150 | 1005 | 1005 | 1005 | 80 | 80 | 80 | 45 | 45 | 45 |
Mainly inductive breaking capacity cos φ = 0,15 | A | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 163 | 163 | 163 | |
Rated earth fault breaking capacity IEC 60265-1(IEC 265) | ||||||||||||||
Earth fault breaking capacity, fig. 6 | I | A | 150 | 150 | 150 | 70 | 70 | 70 | 75 | 75 | 75 | |||
Capacitive breaking capacity, fig. 7 | I | A | 90 | 90 | 90 | 40 | 40 | 40 | 31.5 | 31.5 | 31.5 | 50 | 50 | 50 |
Max. breaking capacity in co-operation with fuses IEC 62271-105 (IEC 420 1990-11) | A | 1600 | 1600 | 1600 | 1600 | 900 | 900 | 300* | ||||||
Max. fuse size2) | In | A | 125 | 125 | 125 | 125 | 80 | 80 | 40 | 40 | ||||
Power frequency withstand voltage 50 Hz 1 min.: | ||||||||||||||
- to earth and between poles | kV | 42 | 45 | 55 | 80 | |||||||||
- across isolating distance | kV | 42 | 60 | 70 | 88 | |||||||||
Impulse withstand voltage 1.2/50 µs: | ||||||||||||||
- to earth and between poles | kV | 75 | 95 | 125 | 170 | |||||||||
- across isolating distance | kV | 85 | 110 | 145 | 195 | |||||||||
Pole distance | mm | 150, 170, 210 | 170, 210 | 1704), 235, 275 | 360 | |||||||||
Max. operating torque at: | 80-100 Nm | |||||||||||||
- closing K/A mech. | Nm | 115-120 Nm | K mech. 80-100 Nm | |||||||||||
- opening K/A mech. | Nm | K mech. 120 Nm/A mech. 3 Nm | / A mech. 3 Nm | |||||||||||
Operating angle on the shaft | degrees | 130 | 120 | |||||||||||
Arc time | ms | 40-60 | 60 |