Vm1medium Voltage Vacuum Circuit-Breakers with Magnetic Drive 12/24/36kv-630/2500A-31.5ka

Breaking Capacity: High Voltage Circuit Breakers
Operation: Energy-storage Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Withdrawable
Structure: Vcb
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
VM1
Poles Number
3
Type
Circuit Breaker
Function
Overcurrent Protection
Certification
ISO9001-2000
Transport Package
Carton
Specification
IEC, GB
Trademark
Rockwill
Origin
China
HS Code
8535210000
Production Capacity
1000PCS

Product Description

General

The VM1 circuit-breakers use vacuum interrupters embedded in the poles.
The embedded interrupters are particularly sturdy and protect the interrupters against shocks, accumulation of dust, and humidity. Each interrupter houses the contacts and makes up the interrupting chamber.
Actuation of the interrupter contacts is carried out by a single magnetic actuator controlled by position sensors and by an electronic module. The energy required for operation is provided by capacitors which ensure an adequate store of energy.

The electronic control circuit can be supplied in two versions: the "basic" one and the one with the "full options" which are characterized by:
  • high electromagnetic immunity
  • self-diagnosis of the capacitor load and the continuity of the coils: controller watchdog with signaling of faults
  • wide range of the auxiliary power supply in direct and alternating current
  • low consumption for maintaining the capacitor load
  • determination of the circuit-breaker state by means of proximity sensors
  • monitoring of all the interruption functions.
 
Thanks to the use of the embedded interrupters and the magnetic drive, the VM1 circuit-breakers guarantee:
  • sturdiness
  • reliability
  • long life
  • no maintenance
magnetic drive technology
the magnetic drive used in the VM1 circuit-breakers generates the run required to activate the moving contacts of the interrupters and integrates all the functions of a traditional drive.
The magnetic drive is a bistable system where the end-of -run positions of the moving armature are reached by means of magnetic fields generated by two coils( one for closing and one for opening).
The moving armature is kept in position by permanent magnets.

 
General characteristics of fixed circuit-breakers
(12-17.5-24kV)
Vm1medium Voltage Vacuum Circuit-Breakers with Magnetic Drive 12/24/36kv-630/2500A-31.5ka
 
 
Circuit-breaker VM1 12
Standards IEC 62271-100 ·
CEI 17-1(file 1375) ·
Rated voltage Ur(Kv) 12
Rated insulation voltage Us(Kv) 12
Withstand voltage at 50Hz Ud(1min)(kV) 28
Impulse withstand voltage Up(Kv) 75
Rated frequency fr(Hz) 50-60
Rated normal current (40ºC) Ir(A) 630 630 1250 1250 1600 1600 2000 2000 2500
Rated breaking capacity(rated symmetrical short-circuit current)  Isc(Ka) 16 16 16 16 - - - - -
20 20 20 20 20 20 20 20 20
25 25 25 25 25 25 25 25 25
31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5
Rated short-time withstand current (3s)  Ik(Ka) 16 16 16 16 - - - - -
20 20 20 20 20 20 20 20 20
25 25 25 25 25 25 25 25 25
31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5
Making capacity Ip(Ka) 40 40 40 40 - - - - -
50 50 50 50 50 50 50 50 50
63 63 63 63 63 63 63 63 63
80 80 80 80 80 80 80 80 80
Operating sequence (O-0.3s-CO-3min-CO) ·
Opening time (ms) 35…45
Acr time   (ms) 10…15
Total interruption time (ms) 45…60
Closing time(ms) 50…60
Mechanical operations(cycles) Actuator …100,000
interrupters …30,000
Electrical operations(cycles) Rated current …30,000
Under short-circuit …50
Maximum overall dimensions   H(mm) 475 475 475 475 599 599 599 599 616
W(mm) 450 570 450 570 570 700 570 700 700
D(mm) 424 424 424 424 424 424 424 424 424
Pole centre distance I(mm) 150 210 150 210 210 275 210 275 275
weight 25Ka(kg) 94 98 94 98 130 135 130 135 135
31.5Ka(kg) 101 105 101 105 130 135 130 135 135
Standardised table of dimensions 1VCD 00001 00002 00001 00002 00003 00004 00003 00004 00004
Operating temperature (ºC) -25…+40
tropicalisation IEC:60068-2-30 ·
721-2-1 ·
Electromagnetic compatibility IEC 60694 ·
(1)the circuit-breakers up to 17.5Kv -1250A-31.5Ka, are made with polyamide poles.
 
 
Circuit-breaker VM1 17
Standards IEC 62271-100 ·
CEI 17-1(file 1375) ·
Rated voltage Ur(Kv) 17.5
Rated insulation voltage Us(Kv) 17.5
Withstand voltage at 50Hz Ud(1min)(kV) 38
Impulse withstand voltage Up(Kv) 95
Rated frequency fr(Hz) 50-60
Rated normal current (40ºC) Ir(A) 630 630 1250 1250 1600 1600 2000 2000 2500
Rated breaking capacity(rated symmetrical short-circuit current)  Isc(Ka) 16 16 16 16 - - - - -
20 20 20 20 20 20 20 20 20
25 25 25 25 25 25 25 25 25
31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5
Rated short-time withstand current (3s)  Ik(Ka) 16 16 16 16 - - - - -
20 20 20 20 20 20 20 20 20
25 25 25 25 25 25 25 25 25
31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5
Making capacity Ip(Ka) 40 40 40 40 - - - - -
50 50 50 50 50 50 50 50 50
63 63 63 63 63 63 63 63 63
80 80 80 80 80 80 80 80 80
Operating sequence (O-0.3s-CO-3min-CO) ·
Opening time (ms) 35…45
Acr time   (ms) 10…15
Total interruption time (ms) 45..60
Closing time(ms) 50…60
Mechanical operations(cycles) Actuator …100,000
interrupters …30,000
Electrical operations(cycles) Rated current …30,000
Under short-circuit …50
Maximum overall dimensions   H(mm) 475 475 475 475 599 599 599 599 616
W(mm) 450 570 450 570 570 700 570 700 700
D(mm) 424 424 424 424 424 424 424 424 424
Pole centre distance I(mm) 150 210 150 210 210 275 210 275 275
weight 25Ka(kg) 94 98 94 98 130 135 130 135 135
31.5Ka(kg) 101 105 101 105 130 135 130 135 135
Standardised table of dimensions 1VCD 00001 00002 00001 00002 00003 00004 00003 00004 00004
Operating temperature (ºC)  
tropicalisation IEC:60068-2-30 ·
721-2-1 ·
Electromagnetic compatibility IEC 60694 ·
(1)the circuit-breakers up to 17.5Kv -1250A-31.5Ka, are made with polyamide poles.
 
 
Circuit-breaker VM1 24
Standards IEC 62271-100 ·
CEI 17-1(file 1375) ·
Rated voltage Ur(Kv) 24
Rated insulation voltage Us(Kv) 24
Withstand voltage at 50Hz Ud(1min)(kV) 50
Impulse withstand voltage Up(Kv) 125
Rated frequency fr(Hz) 50-60
Rated normal current (40ºC) Ir(A) 630 630 1250 1250 1600 2000 2500
Rated breaking capacity(rated symmetrical short-circuit current)  Isc(Ka) 16 16 16 16 16 16 -
20 20 20 20 20 20 -
25 25 25 25 25 25 25
- - - - - - -
Rated short-time withstand current (3s)  Ik(Ka) 16 16 16 16 16 16 -
20 20 20 20 20 20 -
25 25 25 25 25 25 25
- - - - - - -
Making capacity Ip(Ka) 40 40 40 40 40 40 -
50 50 50 50 50 50 -
63 63 63 63 63 63 63
- - - - - - -
Operating sequence (O-0.3s-CO-3min-CO) ·
Opening time (ms) 35…45
Acr time   (ms) 10…15
Total interruption time (ms) 45..60
Closing time(ms) 50…60
Mechanical operations(cycles) Actuator …100,000
interrupters …30,000
Electrical operations(cycles) Rated current …30,000
Under short-circuit …50
Maximum overall dimensions   H(mm) 631 631 631 631 642 642 661
W(mm) 570 700 570 700 700 700 700
D(mm) 424 424 424 424 424 424 424
Pole centre distance I(mm) 210 275 210 275 275 275 275
weight 25Ka(kg) 108 115 108 115 137 137 137
31.5Ka(kg) - - - - - - -
Standardised table of dimensions 1VCD 00005 00006 00005 00006 00007 00007 00007
Operating temperature (ºC) -25…+40
tropicalisation IEC:60068-2-30 ·
721-2-1 ·
Electromagnetic compatibility IEC 60694 ·
(1)the circuit-breakers up to 17.5Kv -1250A-31.5Ka, are made with polyamide poles.
 
 
Vm1medium Voltage Vacuum Circuit-Breakers with Magnetic Drive 12/24/36kv-630/2500A-31.5ka

ATTENTION:

1.The payment term: We accept TT,30% deposit and 70% balance against copy of BL.
2.The delivery time: Usually it will take about 15-20 days.
3.The standard of package: Usually use strong plywood case for protection.
4.The material of transformer: We have two types, one is with copper and another one is with aluminum. It depends on your requirement. In fact, those two have difference if normal work well. Only except the long life. Copper is better and also higher price.
5.The logo: If you have good quantity, it absolute no problem to do OEM.
6.Our market: our products are popular in Indonesia, Philippines, Russia, USA, Middle East and so on. Some of them are our regular customers and some of them are developing. We hope you can join us and make mutual benefit from our cooperation..
7.Warranty: in 12 month since BL date.

OUR SERVICE:

1.quick response in before sales period help you got order.
2.excellent service in production time let you know each step we made.
3.reliable quality solve you after sale headache.
4.long period quality warranty ensure you can buy without hesitate.


WHY CHOOSE ROCKWELL:

1. One-stop supplier globally.
2. More than 10 years professional experiences in electrical appliance industry. 
3.We offer professional online technology support for perfecting your electrical solution free.
4. Experienced sales service and suggestion.
5. All the products with accessories under strict quality control and final inspection before shipping.
6. We can assure the powerful competitive price and reliable quality products.
7. Most competitive shipping rate from our own shipping forwarder.
8. Warranty assurance: 12 month
9. Whatever big or small order, we can provide you one-to-one service.  

CONTACT US:

Contact person: Mr. Chen Chengming
Tel:86-577-27869969
Mobile:86-18668777248
 Vm1medium Voltage Vacuum Circuit-Breakers with Magnetic Drive 12/24/36kv-630/2500A-31.5ka


Your Best Choice for Electrical Appliances Industry!!!
Please leave an inquiry to know more details about Price , Packing ,Shipping and Discount.

Vm1medium Voltage Vacuum Circuit-Breakers with Magnetic Drive 12/24/36kv-630/2500A-31.5ka

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate