Indoor Vacuum Circuit Breaker with Trolley Type

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • Indoor Vacuum Circuit Breaker with Trolley Type
  • Indoor Vacuum Circuit Breaker with Trolley Type
  • Indoor Vacuum Circuit Breaker with Trolley Type
  • Indoor Vacuum Circuit Breaker with Trolley Type
  • Indoor Vacuum Circuit Breaker with Trolley Type
  • Indoor Vacuum Circuit Breaker with Trolley Type
Find Similar Products

Basic Info.

Model NO.
vd4
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed/Drawable
Structure
Vcb
Poles Number
3
Type
Circuit Breaker
Function
Overcurrent Protection
Certification
ISO9001-2000
Transport Package
Carton
Specification
IEC, GB
Trademark
Rockwill
Origin
China
HS Code
8535210000
Production Capacity
1000PCS

Product Description

Product Description

Vd4 Indoor Vacuum Circuit Breaker


Description


VD4 series medium voltage vacuum circuit-breakers with lateral operating mechanism feature the separate pole construction technique.

VD4 vacuum circuit breakers have been designed for indoor use and air insulated switchboards.

Their switching capacity is sufficient to handle any conditions arising from switching of equipment and system components under normal operating and fault conditions, particularly short-circuits, within the parameters of their technical data. The vacuum circuit-breakers of type iVD4, designed in column form, can be supplied both as individual units for fixed installation and mounted on chassis. Vacuum circuit-breakers are characterized by their simple and robust construction. They have a long life expectancy. There is no adverse effect on the vacuum, even from frequent switching of operating and short-circuit currents.
 

Advantages

Vacuum circuit-breakers have particular advantages for use in networks where there is a high switching frequency in the working current range and/ or where a certain number of short- circuit breaking operations are expected. iVD4 vacuum circuit- breakers are suitable for auto reclosing and have exceptionally high operating reliability and long life. The circuit- breakers are notable for their compact design, small dimensions together with high capacity. The operating mechanisms have a low maintenance requirement and the interrupters are maintenance- free throughout their service lives. They are well suited to all load breaking operations which occur in practice, and in particular:
  • Short-circuit currents;
  • Overhead lines under load and, no-load conditions;
  • Cables under load and no-load conditions;
  • Transformers under load and no-load conditions;
  • Generators under load and no-load conditions;
  • Ripple control system;
  • Capacitor banks(also parallel switching) and Motors with starting currents above 600A;
 
Fields of application

Below is the list of SM6 range units used in MV/LV transformer substations and industrial distribution substations:
  • Cable control and protection
  • Overhead control and protection
  • Transformers and distribution substations
  • Motor and transformer control and protection
  • Generator control and protection
  • Capacitor bank control and protection
 



Diagrammatic sketch

Circuit-breaker operating mechanism
A) Open/closed auxiliary contacts
B) Geared motor for closing spring charging
C) Built-in closing spring charging lever
D) Mechanical signalling device for circuit-breaker open/closed
E) Mechanical operation counter
F) Plug-socket connectors of electrical accessories in the truck
G) Signalling device for closing springs charged/discharged
H) Service releases
I) Closing pushbutton
L) Opening pushbutton
M) Operating mechanism locking electromagnet
N) Additional shunt opening release
O) Transient contact
P) Contacts for signalling spring charged/discharged
 
Main characteristics
Rated voltage1) kV 12 24 36 40.5
Rated frequency Hz 50 -60 50 - 60 50 - 60 50 - 60
Rated normal current A 630...40002) 630.25 630...31503) 630...31503)
Rated short-circuit breaking current (symm.) kA 16.31.5 40 50 63 16.31.5 16.4 16.4
Rated short-circuit making current kA 40.8 100 1254) 158 40.8 40.1 40.1
Rated duration of short-circuit4) s 3 3 3 3 3 3 4
Fixed- / withdrawable Version   • / • • / • • / • • / • • / • • / • • / •
Max. overall dimensions
(fixed Version)
mm
p
H
a
b
c
150-275
205-310
450-700
424

461-5996)
210-275
310
570-700
424
5996)
210-275
310
600-750
459
6088)
275
310
750
459
677
210-275
310
570-700
424
631-661
280/3605)
328
8957)/1000
555/6867)
1575
280/3605)
328
8957)/1000
555/6867)
1575
Weight kg 73-105 94-180 147-260 265 100-110 290-365 290-365
Embedded Pole    
Assembled Pole          
 
1) Test voltage according DIN VDE 0670, part 1000, list 2
2) 4000 A with forced cooling
3) 3150 A with forced cooling in AP technology
4) Higher values on request
5) 360 mm for fixed, 280 mm for withdrawable Version
6) Circuit-breaker with heat sink 616 mm
7) Withdrawable Version
8) Circuit-breaker with heat sink 634 mm
Indoor Vacuum Circuit Breaker with Trolley Type


Indoor Vacuum Circuit Breaker with Trolley Type
Indoor Vacuum Circuit Breaker with Trolley Type

Indoor Vacuum Circuit Breaker with Trolley Type
Indoor Vacuum Circuit Breaker with Trolley Type

Indoor Vacuum Circuit Breaker with Trolley Type
Indoor Vacuum Circuit Breaker with Trolley Type

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier