24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Aluminum Alloy
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • 24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
  • 24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
  • 24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
  • 24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
  • 24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
  • 24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
Find Similar Products

Basic Info.

Model NO.
RMR
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Transport Package
Carton
Specification
IEC, GB
Trademark
Rockwill
Origin
China
HS Code
8535210000
Production Capacity
1000PCS

Product Description

Product Description
iSafering SF6 insulated Ring Main Unit
Gas Insulated Ring Main Unit


iSafeRing is a SF6 insulated ring main unit for the secondary distribution network. iSafeRing can be supplied in 10 different configurations suitable for most switching applications in 12/24/36 kV distribution networks. As an option, iSafeRing can be delivered as extendable ring main unit.

Together, iSafeRing represent a complete solution for 12/24/36 kV secondary distribution networks.
C - Cable switch module F - Cable switch module V - Cable switch module
D - Direct cable connection module De - Direct cable connection module with earthing switch M - Metering module

Modularity and external busbar

All modules except the metering module and circuit-breaker module are only 325 mm wide.

Transformer protection

iSafering offers a choice between a switch fuse combination and circuit breaker with relay for transformer protection. The switch fuse combination offers optimal protection against short-circuits, while the circuit breaker with relay option offers better protection against low overcurrents. Circuit breaker with relay is always recommended for larger transformers.

Normal operation conditions

The rated characteristics of the switchgear are valid under the following ambient conditions:
minimum ambient temperature: - 25 °C
maximum ambient temperature: + 40 °C
For different temperature ranges, please contact your UNISUN sales representative.


Standards

iSafeRing/iSafePlus is tested according to following
IEC-standards:
IEC 62271-1/IEC 62271-100/IEC 62271-102/IEC 62271-103/IEC 62271-105/IEC 62271-200/IEC 60529:
 

SF6 insulated Ring Main Unit Outer assembly
24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing

iSafering outer assembly
Upper front cover
1. Manometer
2. Nameplate module
3. Short circuit indicator
4. Capacitive voltage indication
5. Load break / earthing switch position indicator
6. Push buttons close/open operation
7. Charged spring indicator
8. Self-powered protection relay
9. Vacuum circuit-breaker position
10. Operation shaft
11. Padlock device
Lower front cover
12. Nameplate switchgear
13. Fuse blown indicator
14. Disconnector / earthing switch position indicator
15. Capacitive voltage indication
Cable compartment cover
16. Cable compartment cover standard
17. Cable compartment cover with inspection window
18. Support bar (removable)
Side cover
19. Lifting lug
20. Operating handle (standard on right hand side)
 
Inner assembly
24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
 
1. Mechanism compartment
2. SF6 gas tank
3. Cable compartment
4. Pressure relief area

Technical data
SafeRing C-module F-module V-module
Switch disconnector Earthing switch Switch-fuse disconnector Downstream earthing switch Vacuum circuit-breaker Earthing switch/ disconnector
Rated voltage Kv 12/17,5/24 12/17,5/24 12/17,5/24 12/17,5/24 12/17,5/24 12/17,5/24
Rated frequency 5) Hz 50/50/50 50/50/50 50/50/50 50/50/50 50/50/50 50/50/50
Power frequency withstand voltage kV 28/38/50 28/38/50 28/38/50 28/38/50 28/38/50 28/38/50
Lightning impulse withstand voltage kV 95/95/125 95/95/125 95/95/125 95/95/125 95/95/125 95/95/125
Rated normal current A 630/630/630   2001)   200/200/200  
Breaking capacities:              
active load A 630/630/630          
closed loop A 650/650/650          
off load cable charging A 140/140/140          
off load transformer A     20/20/20      
earth-fault A 205/160/160          
earth-fault cable charging A 117/91/91          
short-circuit breaking current kV     see2)   16/16/16  
Making capacity kV 52,5/40/40 52,5/40/40 see2) 12,5/12,5/12,5 40/40/40 40/40/40
Short time current 3 sec. 3) kV 21/16/16 21/16/16     16/16/16 16/16/16
 24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing

24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing
24kv Outdoor Gas Insulated Ring Main Unit 11kv Outdoor Rmu, Free Standing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier