40.5kv Vacuum Circuit Breaker Outdoor Protectors

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • 40.5kv Vacuum Circuit Breaker Outdoor Protectors
  • 40.5kv Vacuum Circuit Breaker Outdoor Protectors
  • 40.5kv Vacuum Circuit Breaker Outdoor Protectors
  • 40.5kv Vacuum Circuit Breaker Outdoor Protectors
  • 40.5kv Vacuum Circuit Breaker Outdoor Protectors
  • 40.5kv Vacuum Circuit Breaker Outdoor Protectors
Find Similar Products

Basic Info.

Model NO.
RVB
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Conventional Circuit Breaker
Poles Number
3
Type
Circuit Breaker
Function
Overcurrent Protection, Circuit-Breaker Failure P
Certification
ISO9001-2000
Transport Package
Wooden
Specification
iec
Trademark
Rockwill
Origin
China
HS Code
85352100
Production Capacity
5000

Product Description

RVB-40.5 outdoor circuit breaker

OUTDOOR SUBSTATION TYPE VACUUM CIRCUIT BREAKER,WITH RATED VOLTAGE UP TO 40.5KV, WITH HIGH RATE CURRENT (UP TO 4000),HIGH SHORT CIRCUIT CURRENT (UP TO 40kA), IN-BUILT CURRENT TRANSFORMER, BEST PROTECTION FOR YOUR TRANSMISSION LINE, MAIN POWER TRANSFORMER, AND BUSBAR


Technical data
No. Item Unit Data
1
Rated voltage KV 12/24/36/40.5
2
Power frequency Wet 42/65/70/95
dry 45/70/80/110
3
Lingthning impluse withstand voltage(peak value) 75/95/125/150/170/185/200
4
Rated current A 630/1250A/1600/2000/2500A
5
Rated short circuit breaking current KA 25/31.5/40
6
Rated capacitor bank breaking current A 600/800
7
Rated short circuit breaking times Times 30
8
Rated making current KA 63/80/100
9
Rated short circuit peak withsatnd current
10
Rated shortcircuit withstand curren 25/31.5/40
11
Rated short time duration time S 3/4
12
Complete breaking time ms ≤100
13
Opening time Highest operate voltage 15~50
Rated operate voltage 15~50
Lowest operate voltage 30~60
14
Closing time 25~50
15
Contact closing bounce time ≤3
Out of simultaneity of contact switching ≤2
Contact overitravel on Opening mm ≤2
16
Mechanical life 20000(Normal)  
17
Electrical life(Rated onload switching) 10000(Noraml)  
18
Rated operate sequence O-0.3-CO-180S-CO
19
Weight ≤250kg



40.5kv Vacuum Circuit Breaker Outdoor Protectors
40.5kv Vacuum Circuit Breaker Outdoor Protectors
40.5kv Vacuum Circuit Breaker Outdoor Protectors
40.5kv Vacuum Circuit Breaker Outdoor Protectors
40.5kv Vacuum Circuit Breaker Outdoor Protectors
40.5kv Vacuum Circuit Breaker Outdoor Protectors
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier