High Voltage Circuit Breaker with Line Protection Relay

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2008-12-08
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • High Voltage Circuit Breaker with Line Protection Relay
  • High Voltage Circuit Breaker with Line Protection Relay
  • High Voltage Circuit Breaker with Line Protection Relay
  • High Voltage Circuit Breaker with Line Protection Relay
  • High Voltage Circuit Breaker with Line Protection Relay
  • High Voltage Circuit Breaker with Line Protection Relay
Find Similar Products

Basic Info.

Model NO.
RCW
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Conventional Circuit Breaker
Poles Number
3
Type
Circuit Breaker
Function
Overcurrent Protection, Circuit-Breaker Failure P
Certification
VDE, ISO9001-2000, CE, CB, CCC
Transport Package
Wooden
Specification
iec
Trademark
Rockwill
Origin
China
HS Code
85352100
Production Capacity
5000

Product Description

KEMA type tested and certificated products!

The ER series automatic circuit reclosers by shorten as auto recloser which can used on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system.and its rated current can reach 1250A.

The ER series auto recloser offers three type smart software for human-computer interaction friendliness application. which functions high efficient and save most cost of time and money expense.

The ER auto recloser offer totally 10curves for user choice as Per standard IEC 62271-111 and IEEC/ANSI C37.60: 5 IEC standard and 5 ANSI standard.
ER series auto recloser also provide with programable software for customized make relay function.

                                         High Voltage Circuit Breaker with Line Protection Relay

ER type recloser offer very importance APP management software insert to distribution automation management system.

                                        High Voltage Circuit Breaker with Line Protection Relay

RCW38M type pole mounted circuit recloser

RCW38M is patented type recloser by Rockwill ELectric.Which has innovation design for magnetic actuator and addtional manual closing for prevent defect of auxiliary power outage moreove the circuit breaker in opening situation case.

RCW38M series recloser is very relieable products, suitable for important position performance.

The main difference between RCW38M and RCW38N:
Type
Close energy
Open energy
Mechanical life
RCW38M
By capacitor charging, fast within 1 S
Need By capacitor release
More than 60,000 times
RCW38N
By motor charging spring, long time 7S~15S
No need capacitor
10,000 times

General:

Rockwill Electric strives to bring our customers the latest technology and competitive pricing and best service for distribution automatic.

The RCW series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. and its rated current can reach 1250A.

The RCW series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.

Service environment:

  a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
  b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
  c) Altitude above sea level: Maximum installation altitude:2500mor more higher.
  d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  e) No frequent violent shake

 
N Item Unit Data
1 Rated voltage kV 15 27 38
2 Rated current A 630 630/1250 630/1250
3 Rated frequency Hz 50/60
4 Power frequency 1min Dry kV 55 65 95
Wet 45 55 80
5 Lightning impulse withstand voltage(peak) kV 95/110 125/165 170/200
6 Rated short circuit breaking current kA 16 16 12.5
7 Rated short current switching current(peak) kA 40 40 31.5
8 Rated peak value withstand current kA 40 40 31.5
9 4S short time withstand current kA 16 16 12.5
11 Rated operating circulate   O-0.5S-CO-2S-CO-2S-CO
10 Breaking current frequency under rated short circuit time 200
12 Mechanism life time 10000
13 Secondary loop 1 min power frequency withstand kV 2